Sunday, April 19, 2009

Upper Stomach Pain And Peeing Alot

Innenausbau und Außendämmung

Moving ahead - in the equipment room are the first tile, the ceilings are suspended there, where they should be, and the first light bulbs perform their duties successfully. The outer insulation (at least 26cm thick) was placed - by the window, jump course, a little "back" what humorless (ok, let's just say "ecologically incorrect * g *) has led contemporaries, our house visually with a" castle "to Compare ...

Sunday, April 12, 2009

How To Make A Mini Dune Buggy

Aller guten Dinge sind drei

The third blower door test has an air change rate 0.7 almost achieved the targets set. With the recent reworking of the discovered vulnerabilities is thus achieve its objective and and we can turn to the next problem: the dwindling schedule.

Can Infection Increase Your Blood Pressure

Osterhase

During the morning ritual of emptying the two condenser us today is Easter Sunday a "something" noticed in a ditch - turned out on closer inspection it as a wounded hare. Imagine your facial expression in front when on Easter Sunday morning call at 10:00 clock to the local police station to tell that a bunny is in the pit. In any case
has picked a squad car, the animal and (hopefully) a suitable Supply transferred. I'm sure the talk of the office for the next few days provided :-)

Monday, April 6, 2009

Cruising Spots In Fort Worth Texas

Es werde Licht

Today we first turned on in our house, the light - in some of the diffusers were installed by an electrician naked light bulbs, a function test of the cabling perform. He also has a cable in the bedroom, which was not published because of a misunderstanding "flush", yet notched a later date.
waits on Thursday the 3rd Attempt by the blower door test - we are excited.

Wednesday, April 1, 2009

13 Dpo Cervix High Soft And Slightly Open

1,3

Big disappointment - in the second experiment, we have clearly missed the target level of 0.6. This time there were at least fairly large temperature differences between inside and outside, so that thermography has provided very clear photos of the vulnerabilities. It turns out that in a passive house in massive construction to avenge the smallest "sin" - in our case has wide finger unplastered points and the intersection points between the base plate, windows and masonry. On the advice of the architect and engineer of the measurement, we will remove another part of the concrete and the outer wall encircling paste with a "foil" to create on the inside of the walls an air-tight connection level. I have insisted on the success of this (and further covered in) action by another blower door test check (hopefully by mid next week). Our architect has come to meet us and take over part of additional costs incurred.
What this all means for our schedule, plus I'm not earlier than thought, if the blower door test is successfully completed.